| DESIGN SHEET: Drip Disposal |
DRIP DESIGN WORKSHEET:
PROPERTY ADDRESS:_____________________________________________ TAX MAP #._________________PHONE:____________ DESIGNER'S NAME:__________________________ |
- _____ GALLONS PER DAY_________BEDROOMS         Date:_____________
- _____ GPD/L.F. SOIL LOADING RATE
- _____ FT. X _____ FT. AREA FOR DISPOSAL LAYOUT a)_____ FT2
- _____ GPD/FT2 SOIL LOADING RATE PROVIDED ( #1 / # 3a )
- _____ ZONES
- _____ TOTAL DRIPPER LINE PROVIDED
- _____ SEPTIC TANK SIZE
- _____ DOSING TANK SIZE
- _____ GALLONS PER INCH DOSING TANK
- ZONE ONE
- _____ TOTAL ABSORPTION AREA
- _____ LINEAR FEET DRIPPER LINE
- _____ LONGEST LATERAL LENGTH
- _____ DOSING FLOW RATE
- _____ NUMBER OF RETURN FIELD FLUSH CONNECTIONS
- _____ FIELD FLUSH FLOW RATE
- _____ TOTAL FLOW REQUIRED
- ZONE TWO
- _____ TOTAL ABSORPTION AREA
- _____ LINEAR FEET DRIPPER LINE
- _____ LONGEST LATERAL LENGTH
- _____ DOSING FLOW RATE
- _____ NUMBER OF RETURN FIELD FLUSH CONNECTIONS
- _____ FIELD FLUSH FLOW RATE
- _____ TOTAL FLOW REQUIRED
- ZONE THREE
- _____ TOTAL ABSORPTION AREA
- _____ LINEAR FEET DRIPPER LINE
- _____ LONGEST LATERAL LENGTH
- _____ DOSING FLOW RATE
- _____ NUMBER OF RETURN FIELD FLUSH CONNECTIONS
- _____ FIELD FLUSH FLOW RATE
- _____ TOTAL FLOW REQUIRED
- ZONE FOUR
- _____ TOTAL ABSORPTION AREA
- _____ LINEAR FEET DRIPPER LINE
- _____ LONGEST LATERAL LENGTH
- _____ DOSING FLOW RATE
- _____ NUMBER OF RETURN FIELD FLUSH CONNECTIONS
- _____ FIELD FLUSH FLOW RATE
- _____ TOTAL FLOW REQUIRED
- _____ MAXIMUM DESIGN FLUSHING FLOW
- _____ FEET HEAD LOSS HYDRAULIC UNIT (BASED ON # 42)
- HYDRAULIC UNIT SUPPLY LINE SIZE (1-1/2" TYPICAL)
- _____ INCHES PIPE
- _____ LENGTH SUPPLY PIPE
- _____ FT. STATIC LIFT (CENTRAL UNIT ELEVATION - OFF FLOAT ELEVATION)
- _____ TOTAL FEET HEAD LOSS LINE (DYNAMIC HEAD LOSS + #47)
- FORCE MAIN SUPPLY LINE PIPE SIZE & LENGTH
- _____ ZONE ONE SIZE, _____ ZONE ONE LENGTH _____ FEET HEAD LOSS
- _____ ZONE TWO SIZE, _____ ZONE TWO LENGTH _____ FEET HEAD LOSS
- _____ ZONE THREE SIZE, _____ ZONE THREE LENGTH _____ FEET HEAD LOSS
- _____ ZONE FOUR SIZE, _____ ZONE FOUR LENGTH _____ FEET HEAD LOSS
- RETURN FLUSH LINE SIZE & LENGTH
- _____ ZONE ONE SIZE, _____ ZONE ONE LENGTH _____ FEET HEAD LOSS
- _____ ZONE TWO SIZE, _____ ZONE TWO LENGTH _____ FEET HEAD LOSS
- _____ ZONE THREE SIZE, _____ ZONE THREE LENGTH _____ FEET HEAD LOSS
- _____ ZONE FOUR SIZE, _____ ZONE FOUR LENGTH _____ FEET HEAD LOSS
- _____ FEET HEAD LOSS TOTAL STATIC (VERTICAL LIFT)
- TOTAL PRESSURE LOSS ( ADD ITEMS; 43,48,50-53,55-58,59,+FLUSHING)
- _____ ZONE ONE HEAD LOSS, INCLUDES _____ FEET FLUSHING
- _____ ZONE TWO HEAD LOSS, INCLUDES _____ FEET FLUSHING
- _____ ZONE THREE HEAD LOSS, INCLUDES _____ FEET FLUSHING
- _____ ZONE FOUR HEAD LOSS, INCLUDES _____ FEET FLUSHING
- PUMP SIZING
- _____ MAXIMUM PRESSURE LOSS TOTAL (HIGHEST FEET 61-64)
- _____ DISC FILTER BACKFLUSH (#48 + 115' @15 GPM)
- _____ GPM @ _____ FEET (LARGER OF 66 & 67)
- PUMP MODEL___________________
- _____GPM @ _____FEET _____VOLTS _____PHASE _____HP
- TIME DOSING PER ZONE
- Two Zone Standard Enable           (180 min rest)
- Two Zone Peak Enable           (108 min rest)
- Four Zone Standard Enable           (90 min rest)
- Four Zone Peak Enable           (54 min rest)
- ZONE ONE____ GPM ____MIN/DOSE ____AVE. CYCLES ____PEAK CYCLES____GAL/DOSE
- ZONE TWO____ GPM ____MIN/DOSE ____AVE. CYCLES ____PEAK CYCLES____GAL/DOSE
- ZONE THREE ____ GPM ____MIN/DOSE ____AVE. CYCLES ____PEAK CYCLES____GAL/DOSE
- ZONE FOUR ____ GPM ____MIN/DOSE ____AVE. CYCLES ____PEAK CYCLES____GAL/DOSE
- _____ INCHES DRAWDOWN FLOAT SWITCH SETTING (MINIMUM 4")
|
|