- The vertical lift is the elevation difference between the "off float" and the highest point in any zone.
- The diameter of the pipe from the pump tank to the hydraulic unit is 1-1/2" minimum.
- All supply and return pipes are 1".
- The flush return pipe from the hydraulic unit to the pretreatment tank is 1-1/2" gravity.
- The maximum distance from the pump tank to the hydraulic unit is 30'.
- The tables may be used with the standard zone detail configuration only. A calculation sheet must be filled out for any other configuration.
- Top feed manifolds must be used when any discernible slope is encountered.
|
|
| Maximum Static Lift ("Off Level Float" to Drip Field) |
|   |   |   |   |   |   |   |   |
|   | Supply/ |   |   |   |   |   |   |
| 1 | Return Line | 2-Lat | 3-Lat | 4-Lat | 5-Lat | 6-Lat | 7-Lat |
|   | (feet) | 300' | 300' | 300' | 240' | 165' | 100' |
| 2 |   |   |   |   |   |   |   |
| 3 | 100 | 98 | 88 | 75 | 74 | 79 | 77 |
| 4 | 150 | 96 | 84 | 69 | 66 | 70 | 68 |
| 5 | 200 | 94 | 81 | 63 | 58 | 61 | 59 |
| 6 | 250 | 92 | 77 | 57 | 51 | 52 | 49 |
| 7 | 300 | 90 | 73 | 50 | 43 | 44 | 40 |
| 8 | 350 | 88 | 70 | 44 | 35 | 35 | 31 |
| 9 | 400 | 86 | 66 | 38 | 27 | 26 | 21 |
| 10 | 450 | 84 | 63 | 32 | 19 | 17 |   |
| 11 | 500 | 82 | 59 | 26 | 12 |   |   |
| 12 | 550 | 80 | 55 | 20 |   |   |   |
| 13 | 600 | 78 | 52 | 14 |   |   |   |
| 14 | 650 | 76 | 48 | 8 |   |   |   |
| 15 | 700 | 74 | 45 | 2 |   |   |   |
| 16 | 750 | 72 | 41 |   |   |   |   |
| 17 | 800 | 70 | 37 |   |   |   |   |
| 18 | 850 | 68 | 34 |   |   |   |   |
| 19 | 900 | 66 | 30 |   |   |   |   |
| 20 | 950 | 64 | 27 |   |   |   |   |
| 21 | 1000 | 62 | 23 |   |   |   |   |
|