MODEL NUMBERING SYSTEM & OPTIONS
Standard and custom control panels are easily specified and ordered by completing the simple panel guide below. Panel pricing can be obtained by starting with a base panel list price found in the design section and adding the list prices of the desired options with panel point upgrades.

    
--
 
Control SeriesA-Alarm Option"B"-Motor Protect*Enclosure Type
--
Control Panel Options

Control Series:SSimplex controlSEQSimplex equalization control
DDuplex controlSEPRSimplex equalization control
TTriplex controlSEPRTSimplex equalization control
QQuadplex controlDEPRDuplex equalization control
MMulti-plex control (five or more)DEPRTDuplex equalization control
METMulti-plex Equalization controlMTMultiplex Timer control on demand
CSEPRCombination Repeat Cycle Time controlCSEPRTCombination equalization control
Alarm Option:(A) Indicator Light & Buzzer On Indoor Units, Red Light & Buzzer On Outdoor Units
 
Breaker Option:Place "B" for Breaker in designated space followed by the desired phase and voltage code.
PHASE:1-Single phase3-Three phase
VOLTAGE:1-120V2-240V4-460V8-208V
On 3 phase systems, motor protectors are substituted for breakers and require a "P" instead of the "B". If fusible disconnects for pumps are desired in place of pump breakers then replace the "B" with an "F", followed by the desired phase and voltage.

Enclosure Option:1-NEMA 12-NEMA 123-NEMA 3R4-NEMA 4X
 
Standard Options List:
*A-Auto Reset Alarm Circuit
B-Bell/Horn (4" weatherproof)
*C-Cycle Counter
D-Delayed Lag Pump Timer
*E-Elapsed Time Meter
*F-Flasher
F(L)-Flashing Light
F(S)-Flashing Strobe Light
F(C)-Flashing Light W/ Protective Cage
G-Gell Cell Battery
H-Hinged Inner Door
I(5)-Intrinsically Safe Float Switch Relays (508)
I(9)-Intrinsically Safe Float Switch Relays (913)
*J-Contactor/Breaker Upgrade
K-"K" Pack Installation Kit
L-Locking Hasp
L(1)-Lightning Arrestor 1 Wire W/ Gnd
L(2)-Lightning Arrestor 2 Wire W/ Gnd
L(3)-Lightning Arrestor 3 Wire W/ Gnd
L(4)-Lightning Arrestor 3 Wire W/ Gnd(460)
M-Main Breaker/Disconnect
N-Nema Rated Starter
O-Override Switch For Alternator
P(C)-Pump Fail Circuit By Current Sensor
P(F)-Pump Fail Circuit By Flow Switch
Q-Quick Disconnect Operator
*R-Redundant Off Float Switch
R(A)-Redundant Off With Alarm
S-Seal Fail Indicator
S(R)-Seal Fail Relay W/ Indicator
S(A)-Seal Fail Relay W/ Alarm
T-Thermal Cut-out
T(I)-Thermal Cut-out With Indicator
T(A)-Thermal Cut-out With Alarm
U-Utility Receptacle
U(G)-Utility Receptacle (GFI)
U(W)-Utility Receptacle (Weatherproof)
V-Voltage Monitor
V(P)-Voltage/Phase Monitor
W-Weather Heater
W(1)-Weather Heater W/ Blower(100W)
W(2)-Weather Heater(200W)
X-Extra Options
Y-24 Volt Float Switch Circuit
Z-Oiltight Lights & Switches
* Standard Options